Support:+1 929 202 3014 info@abvigenus.com

Services

Custom Polystyrene Particles Conjugation

  • Overview
  • Service Details
  • Service Highlights
  • Related Services
  • Case Study
  • How to order
  • Overview

    Service Number£ºASZX002

    Abvigen provides customers with custom polystyrene particles convergence service, using various types of Polystyrene Particles to form strong bonds with antibodies, proteins, or other biomolecules.

    Abvigen can provide the following three methods for attaching biological ligands to polystyrene particles: Passive adsorption method Biotin-Streptomycin method and EDC Covalent coupling method.The passive adsorption method assembles antibodies or proteins onto the surface of polystyrene particles through electrostatic adsorption. This method is convenient, fast, and does not involve chemical reactions. The Biotin Streptomycin method utilizes polystyrene particles modified on the surface of streptomycin to bind with biotinylated proteins, resulting in a product with good stability. The EDC Covalent coupling method utilizes EDC and NHS to activate the surfaces of polystyrene particles and proteins to be bound. This method is more controllable and can effectively reduce the impact of steric hindrance on the structure of conjugated proteins.


    Service Details

    Passive adsorption

    1.Mix the standard phosphate buffer, protein solution to be coupled, and polystyrene particle dispersion solution, vortex and incubate for a period of time.

    2.Centrifuge unreacted protein and clean to remove impurities

    3.Analyze products to ensure compliance with customer requirements and obtain the final product

     

    Biotin-Streptomycin method

    1. Combine the protein to be conjugated with biotin to obtain biotinylated protein

    2. Polystyrene Particles modified with streptomycin bind to biotinylated proteins

    3.Centrifuge unreacted protein and clean to remove impurities

    4.Analyze products to ensure compliance with customer requirements and obtain the final product

     

    EDC Covalent coupling

    1. EDC and NHS are added to the buffer solution in proportion to prepare the EDC-NHS active solution, adjust the pH value, add disperse the polystyrene particles, and activate the surface of the polystyrene particles?.

    2. Mix the biomacromolecules to be coupled (such as proteins, peptides, etc.) with EDC-NHS active solution in a certain proportion, and let them stand for a certain period of time for crosslinking reaction.

    3.Centrifuge unreacted protein and clean to remove impurities

    4.Analyze products to ensure compliance with customer requirements and obtain the final product


    Application

    Targeted drug delivery

    Biological testing

    Cell surface markers

    Biosensors

    Cell imaging


    Service Highlights

    Convenient and fast

    Customer can select buffer

    Customer can select polystyrene particlestype size

    Multiple protein antibodies can be selected


    Related Services
    Case Study
    How to order

    Ordering Information

    Website: www.abvigen.com  

    Phone: +1 929-202-3014  

    Email: info@abvigenus.com


    Previous: Custom Magnetic Particles Conjugation Next: None!